Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Membranes (Basel) ; 12(10)2022 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-36295753

RESUMEN

Selective, nanometer-thin organosilica layers created by plasma-enhanced chemical vapor deposition (PECVD) exhibit selective gas permeation behavior. Despite their promising pure gas performance, published data with regard to mixed gas behavior are still severely lacking. This study endeavors to close this gap by investigating the pure and mixed gas behavior depending on temperatures from 0 °C to 60 °C for four gases (helium, methane, carbon dioxide, and nitrogen) and water vapor. For the two permanent gases, helium and methane, the studied organosilica membrane shows a substantial increase in selectivity from αHe/CH4 = 9 at 0 °C to αHe/CH4 = 40 at 60 °C for pure as well as mixed gases with helium permeance of up to 300 GPU. In contrast, a condensable gas such as CO2 leads to a decrease in selectivity and an increase in permeance compared to its pure gas performance. When water vapor is present in the feed gas, the organosilica membrane shows even stronger deviations from pure gas behavior with a permeance loss of about 60 % accompanied by an increase in ideal selectivity αHe/CO2 from 8 to 13. All in all, the studied organosilica membrane shows very promising results for mixed gases. Especially for elevated temperatures, there is a high potential for separation by size exclusion.

2.
ACS Appl Mater Interfaces ; 14(8): 10907-10916, 2022 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-35179345

RESUMEN

In this work, quartz crystal microbalance with dissipation monitoring (QCM-D) was used to develop a new method to evaluate the protein repellency of microgel coatings. Compared to traditional protocols for surface analysis, QCM has the advantage of a real-time quantitative approach with high sensitivity, allowing us to describe variations of the adsorbed mass with unprecedented accuracy. To enable the detectability of the film throughout the whole operational temperature interval, a poly(N-isopropylacrylamide-co-glycidyl methacrylate) p(NIPAm-co-GMA) microgel monolayer with defined thickness and rigidity was designed. Covalent adhesion of the film to the silica surface was achieved by epoxy-thiol click chemistry and tested for repeated temperature cycles, showing substantial reproducibility. Further functionalization of microgel surfaces by grafting polyzwitterionic chains remarkably improved the protein repellence leaving the strong surface adhesion unaltered. Before and after exposure to fluorescein-tagged bovine serum albumin (FITC-BSA), the coatings showed identical responsive behavior, proving the absence of protein deposition. In nonrepellent coatings, QCM monitoring instead displayed a characteristic shift in the volume phase transition (VPT), pointing out the effect of adsorbed proteins on the swelling behavior of pNIPAm. The combination of QCM-D and UV-visible (UV-vis) was used to evaluate the effect of increasing surface coverage, enabling to distinguish between the protein deposition occurring over the coated and the uncoated portion of the sensor.

3.
Sci Rep ; 11(1): 24490, 2021 12 29.
Artículo en Inglés | MEDLINE | ID: mdl-34966168

RESUMEN

During the first wave of Covid-19 infections in Germany in April 2020, clinics reported a shortage of filtering face masks with aerosol retention> 94% (FFP2 & 3, KN95, N95). Companies all over the world increased their production capacities, but quality control of once-certified materials and masks came up short. To help identify falsely labeled masks and ensure safe protection equipment, we tested 101 different batches of masks in 993 measurements with a self-made setup based on DIN standards. An aerosol generator provided a NaCl test aerosol which was applied to the mask. A laser aerosol spectrometer measured the aerosol concentration in a range from 90 to 500 nm to quantify the masks' retention. Of 101 tested mask batches, only 31 batches kept what their label promised. Especially in the initial phase of the pandemic in Germany, we observed fluctuating mask qualities. Many batches show very high variability in aerosol retention. In addition, by measuring with a laser aerosol spectrometer, we were able to show that not all masks filter small and large particles equally well. In this study we demonstrate how important internal and independent quality controls are, especially in times of need and shortage of personal protection equipment.


Asunto(s)
COVID-19/prevención & control , COVID-19/transmisión , Máscaras/estadística & datos numéricos , Aerosoles , Filtración/instrumentación , Alemania , Humanos , Máscaras/normas , Máscaras/tendencias , Respiradores N95/normas , Respiradores N95/estadística & datos numéricos , Exposición Profesional/prevención & control , Pandemias/prevención & control , Equipo de Protección Personal/normas , Control de Calidad , Dispositivos de Protección Respiratoria/normas , SARS-CoV-2/patogenicidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...